HVAC calculators for homeowners
Fourteen calculators and three guides for what a heating and cooling system actually raises: how big, how much air, what it costs to run, what it costs to replace, and whether it is worth repairing at all.
Load and size
How much heating and cooling the house needs, and why the square-footage chart is wrong.
AC Tonnage Calculator
Size the air conditioner from envelope, glass, climate and ducts, and see the square feet per ton your inputs imply.
SizingRoom BTU Calculator
Build a single room's cooling load from glass area, orientation, people and equipment watts.
SizingHVAC Load Calculator
Block load for the whole house — cooling in tons, heating in BTU per hour, and the furnace size that follows.
Airflow and ducts
The third variable in every capacity equation, and the duct system that delivers it.
What it costs to run
Efficiency ratings turned into dollars, with the crossover points worked out.
SEER2 Savings Calculator
Turn an efficiency rating into annual kWh and dollars, and see how long the premium takes to repay.
Running costHeating Cost Comparison
Gas, propane, oil, electricity, heat pumps, wood and pellets on one scale: dollars per million BTU.
Running costHeat Pump vs Furnace
Annual heating cost for both, with the auxiliary heat that fills in below the balance point.
Running costThermostat Setback Calculator
What a nightly setback actually saves, from the temperature difference and the hours — not a flat percentage.
What it costs to install
Line-item cost models instead of a national average that nobody pays.
AC Replacement Cost
Equipment, labour hours, materials, permit, disposal and margin, itemised the way a quote should be.
Installed costFurnace Replacement Cost
Price a furnace by output, AFUE and venting route, and see why 80 versus 90 is a flue decision.
Installed costHeat Pump Cost
Air-source, cold-climate or dual fuel, including the electrical work that turns a quote into a bigger one.
Installed costMini-Split Cost
Per zone, per head, per line-set foot — and when several singles beat one multi-zone condenser.
Installed costDuctwork Cost
Replacement by linear foot and register count, with the sealing comparison beside it.
Decisions, not calculators
The questions a number cannot answer: how cold is too cold, repair or replace, which refrigerant.
Heat Pump in Cold Weather
Capacity at 47, 17 and 5 F, the balance point, and when backup heat takes over.
GuidesRepair or Replace
The 50 percent rule, equipment life, and what each common repair actually costs.
GuidesR-410A Phase-Out
The GWP 700 limit, the deadline that moved, and what owners can still do.
Start with the load, not the equipment
Almost every expensive HVAC mistake is a sizing mistake wearing a different costume. A system that is 50 percent too large cools the house in four minutes, shuts off before the coil has pulled any moisture out of the air, and leaves the rooms cold and clammy at the thermostat setting. A furnace that is two sizes too big cycles the heat exchanger through more thermal stress than it was designed for and runs at a temperature rise the rating plate never specified. Neither failure looks like a sizing problem from the driveway, and neither is fixed by a better brand.
So this cluster starts at the beginning. The tonnage page, the room BTU page and the block load page all answer the same underlying question at different scales, and they share one model, which is why the numbers agree with each other. That consistency is not a flourish: a calculator site whose pages contradict each other is telling you the numbers were invented separately.
What the calculators have in common
Every load calculation here is a block load — the same structure ACCA Manual J uses before it splits a house into rooms. Conduction through the shell is area divided by R-value times the temperature difference. Infiltration is air changes per hour times volume times 0.018. Internal gains come from people at 230 BTU per hour sensible each and equipment at 3.412 BTU per hour per watt. Solar comes through the glass, weighted by orientation, and duct gain comes from wherever the ducts run. Add the terms, and the total is the load.
Showing the terms is the point. A single number with no breakdown cannot be argued with, checked, or corrected for a house that is unusual in one specific way. A table that says "your west glass is 41 percent of your cooling load" tells you what to do about it, and it tells you when the estimate is drifting away from your house.
Running cost and installed cost are different questions
Whether a heat pump beats a furnace is a fuel-price question with a weather input, and it has a definite answer that changes when either price moves. Whether it is worth installing one is a capital question that also depends on what the equipment replaces, what the electrical service can support, and what rebates exist at your address. Mixing the two is how a $19-per-million-BTU operating argument gets used to justify a $9,000 installation without anyone doing the second calculation.
The cost pages therefore itemise. Equipment, labour hours at a regional rate, materials, permit, disposal, and a visible overhead-and-margin line. The last one matters: a 3-ton job whose parts and labour come to $3,700 is not sold for $3,700, and a homeowner comparing three quotes deserves to see which portion of the price is the work and which is the company.
The three numbers people mix up
Tons, BTUs and CFM measure different things and get used interchangeably in conversation. A BTU is a quantity of heat; BTU per hour is the rate at which heat moves; a ton is 12,000 BTU per hour, so it is a rate wearing a different hat. CFM is air volume per minute, which is how the rate gets delivered to a room. A 3-ton system moves about 1,200 CFM at nominal conditions, which means it carries roughly 8,600 BTU per hour of sensible heat per 400 CFM at a 20 degree split. When someone says “the system is short of capacity”, they could mean any of the three.
SEER2, HSPF2 and AFUE are seasonal efficiency ratings for three different machines. SEER2 covers cooling, HSPF2 covers heat pump heating, and AFUE covers combustion heating. They are not comparable to each other and none of them is linear: moving from 14 to 15 SEER2 saves 6.7 percent, moving from 20 to 21 saves 4.8 percent. The 2023 test procedure also made SEER2 read about 4.5 percent lower than the old SEER for identical equipment, which is why a 16 SEER unit is a 15.2 SEER2 unit and why a comparison across the two ratings has to be converted before it means anything.
Design temperature and average temperature decide the size and the bill respectively. Equipment is sized at the 1 percent summer and 99 percent winter design temperatures — the hours a year that are more extreme than the design — while annual energy is computed from the average, weighted by hours. Confusing the two produces either a system that cannot keep up on the worst week or an energy estimate that is wrong by a factor of three.
What is deliberately not here
No lead forms, no brand rankings, no "average cost in your area" that resolves to a phone number. This site does not sell installation leads, which is why the pages can tell you that a 3-ton system is often oversized, that a $2,200 efficiency premium takes forty years to repay, and that the federal tax credit most contractors still quote on their paperwork expired at the end of 2025. Those are all things a lead-generation site has a commercial reason not to say.
Frequently asked questions
Why is there no "get three free quotes" form on these pages?
Because this site does not sell leads. Most HVAC calculators on the web exist to capture a phone number and sell it to contractors, which is why their numbers are vague and their advice is always "call a professional in your area". These pages compute, explain the formula, and leave you to call whoever you like.
How accurate are the load numbers?
A block load built from honest inputs lands within roughly 15 percent of a room-by-room Manual J, which is enough to catch a quote that is 50 percent oversized and not enough to submit for a permit. The two inputs people get wrong most often are glass area and air-tightness, both of which are easy to overstate in your own favour.
Why do two pages give the same number for the same house?
Because they call the same model. The tonnage page, the room BTU page and the block load page share one engine, so a 2,000 square foot house in zone 4 returns 2.45 tons on all of them. Calculator sites that disagree with themselves are the reason this matters.
Are these installed-cost figures real?
They are built from published equipment prices, labour rates and permit ranges, itemised so you can see each one, with a regional multiplier and a visible overhead-and-margin line. They are not quotes, and local pricing can fall outside the range — but you can see exactly which line your quote is inflating.
Where do the design temperatures come from?
Each climate zone uses representative 1 percent cooling and 99 percent heating design temperatures for the middle of the zone, not for your county. If you know your county's numbers from a permit set or a contractor's calculation, type them into the load calculator and the result becomes materially more useful.
Do you cover rebates?
Only to say what exists and what has expired. The federal Section 25C and 25D credits ended for equipment placed in service after December 31, 2025, so a 2026 installation gets nothing from the IRS. State and utility programs remain in many states and vary by address, which is more than a national page can resolve honestly.